Description
- Current not consistency
- Part rejection very high
- Worry of welding quality
- High power input consumption
- Long weld time
- Change new super inverter mesa AIT series
- No need controller
- No need thyristor
- Old machine parts service
- Working Smooth
- Good output quality
- Constant current output
- Low power input (40% lower compare AC machine)
- Shorter weld time
Specification
| Type | For Spot and Projection welding machine | For Seam welding machine | |||||||
| AIT-724-4 AIT-1124-4 AIT-1624-4 | AIT-544-4 AIT-844-4 AIT-1044-4 AIT-1644-4 | AIT-826-4 | AIT846-4 | ||||||
| Power Supply | Three phase A.C.200V/220V±10% | Three phase A.C.400V/440V±10% | |||||||
| Frequency | 50/60Hz | ||||||||
| Output voltage | Single phase 300V (Peak value A.C.220V) | Single phase 600V (Peak value A.C.440V) | |||||||
| Output frequency | Standard settings 50 or 60 Hz synchronous to frequency of power supply. Also frequency can be set from 20 to 180Hz by each 1Hz | ||||||||
| Output current | 700 | 1100 | 1600 | 500 | 800 | 1000 | 1600 | 800 | 800 |
| Rated capacity | 75 | 118 | 173 | 108 | 173 | 216 | 346 | 214 | 429 |
| Maximum capacity | 210 | 330 | 480 | 300 | 480 | 600 | 960 | 240 | 480 |
| Rated duty cycle | 6.5 | 40 | |||||||
| Control method | Primary or secondary constant current by PWM control | ||||||||
| Repeated output currency accuracy | Repeated accuracy is within ±3% of scale by primary control
Repeated accuracy is within ±3% of scale by secondary control |
||||||||
| Straight line accuracy | Straight line accuracy is within ±5% of full scale | ||||||||
| Setting of welding current | By program box or analog input | ||||||||
| Setting of welding condition | 7/15/31/63/127 Conditions | ||||||||
| Control unit | Time unit : 1 cycle (1msec unit can be set without heat time)
Weelding current unit : 100A or 1A |
||||||||
| Maximum welding condition | 127 welding conditions, 7 transformers and 2 solenoid valves | ||||||||
| Output squeeze solenoid valve | Each circuits of A.C.100V and D.C.24V can be selected | ||||||||
| Function of EP solenoid valve | Three pressure can be set by two electric and pneumatic proportional solenoid valve circuits (option) | ||||||||
| Mass | 29 | 40 | 86 | 29 | 40 | 42 | 86 | 63 | |
| Lead beaker capacity | 150A | 225A | 350A | 100A | 175A | 200A | 350A | 400A | 400A |
| Input cable | 22sq
M8 |
38sq
M8 |
150sq
M12 |
14sq
M8 |
38sq
M8 |
38sq
M8 |
150sq
M12 |
100sq
M12 |
100sq
M12 |
| Output cable | 60sq
M8 |
100sq
M10 |
200sq
M12 |
38sq
M8 |
60sq
M10 |
80sq
M10 |
200sq
M12 |
150sq
M12 |
150sq
M12 |
| Amount of cooling water | 3L/min, AIT-825-4 & AIT-846-4 is 5L/min | ||||||||
| Temperature of cooling water | 30ºC or less | ||||||||


PDF Download
![]()
ac inverter